XLPE Insulated cableDetails Type: Copper/XLPE /PVC This series is mainly laid indoor, cableslot, direct burial, channel, XLPE Insulated cable.8.7/15KVpowe Product DescriptionXLPE Insulated cableStandard and Propertyfor Using The products can be produced according to our factory specificationwhich is equivalent to the standard IEC60502. The factory can alsodesign and manufacture special XLPE cable according to the otherstandards required by the customers. They not only have excellentelectric, mechanical properties, but also have powerful resistanceagainst chemical corrosion, heataging and environmental stress.Their structures are simple. The permissible maximum operatingtemperature is 90'C. It is convenient for using, and they can belaid with no restriction of different elevation.Rate Voltage(kv)Sectional Area(mm 2 )No.of Core1stclass0.6/11.8/33.6/66/108.7/1512/2018/3021/352ndclass1/13/36/68.7/1012/1518/20-26/351Core 1.5-80025-80025-120025-120035-120050-120050-120050-12002Core 1.5-18525-185 3Core 1.5-40025-40025-40025-40035-40050-40050-40050-4004Core 2.5-40025-400 5Core 2.5-40025-400 TypeNameMain ApplicationCu CoreAl CoreYJV YJYYJLV YJLVXLPE insulated,PVC or PE Sheathed Power CableFor layingindoor,tunnel,channel and undergroud,Unable to bear externalmechanical force,but bear the traction force during laidYJV22 YJV22YJLV22 YJV22XLPE Insulated,Steel Tape Armoured,PVC or PE Sheathed PowerCableFor laying indoor,tunnel,channel and undergroud Able to bearexternal mechanical force,but unable to bear large pullingforceYJV32 YJV32YJLV32 YJLV32XLPE Insulated,Fine Steel Wire Armoured,PVC or PE SheathedPower CableFor laying in shaft with large difference of level.Ableto bear external machanical force and maderate pullingforceYJV42 YJV42YJLV42 YJLV42XLPE Insulated,Thick Steel Wire Armoured,PVC or PE SheathedPower CableAble to bear positive pressure and pulling force Note:"ZR-"Include ABC three kinds of flame retardent cables,whichare spectively indicated in "ZRA-" or "ZRB-" "ZRC-".Forexample:"ZRB-YJV","ZRA-YJV22". Main Technical Quota 1.DC resistance:conductor resistance of finished cable at 20C perkilometer is not more than the following values. Nominal Section Area(mm 2 )1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400500 630 800Copper Core12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.5240.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.03660.0283 0.0221Aluminum Core18.1 12.1 7.41 4.61 3.08 1.91 1.20 0.8680.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.778 0.0605 0.04690.0367 2.Voltage Test and Partial Discharge Test Rate Voltage Uo(kv)Item0.6/11.8/33.6/66/6 6/108.7/10 8.7/1512/2018/20 18/3021/3526/35VoltageTest Voltage3.56.512.52130.5426373.591TestTime555555555Partial Discharge TestTestVoltage--6.210.415.120.831.136.345DischargeCapacity--10101010101010 XLPE Insulated cable XLPE Insulated cable |
Company QR code Anytime Anywhere Mobile |